SMC Liquid Flow Sensor Series PF3W/LFE/PFUW
Digital | Water / Coolant / Conductive Fluid | 0.5~250 L/min | IO-Link 1.1 | IP65
The liquid flow sensor delivers real-time flow readings and can be installed independently or configured as a manifold with an integrated display or remote display paired with a panel-mounted monitor. It is categorized into four types based on installation and readout methods: - **Integrated Display Type**: Set up and read directly at the operation point. - **Remote Type**: Installed in remote or confined spaces, providing analog output for sensor monitoring or HMI reading. - **Monitor Type**: Features a digital display and can be mounted near the panel or control console. - **Manifold Type**: Integrates up to 10 water or coolant lines into a compact array, supplied by a single main supply and return line. This reduces piping design and assembly time. Each line can be equipped with remote or integrated display sensors, temperature sensors, flow control valves, and check valves, and is compatible with IO-Link. The PF3W uses the Karman vortex principle for flow detection, while the LFE operates on Faraday electromagnetic induction. Both feature no obstructions or moving parts within the flow path, resulting in low pressure loss and allowing flow direction changes after installation. The PFUW is a clamp-on type where the sensor remains outside the pipe without contacting the liquid.
Parameters are subject to the manufacturer's sample and final solution confirmation.
Core Features
Integrated display model: Equipped with buttons and a display for setting parameters and reading values at the operation station.
Remote: Ideal for remote or constrained spaces; provides analog output for monitoring or HMI access.
Monitor type: Digital display, for installation near the panel or console
Manifold type: Up to 10 integrated water or coolant channels with a single main supply/return line; IO-Link compatible
PF3W7-Z: Dual-screen, 3-color display; IP65; 0.5~250 L/min; optional flow control valve and temperature sensor
PF3W7-L: IO-Link 1.1 (COM2), 48-bit process data with flow, temperature, switch outputs, and diagnostics
PF3W7-U: PVC piping, suitable for deionized water and liquid chemicals; does not include control valves or temperature sensors.
PF3W7-X365: SUS316 Stainless Steel Compression Fitting with EPDM Seal, Compatible with Fluorinated Fluids such as Fluoroil
LFE: Electromagnetic, no flow-restricting or moving parts; 0.5~200 L/min; low pressure drop
PFUW: Clamp-on, external mounting, IP67, no leak points, no clogging, no pressure loss
Optional: mounting bracket, M8 or M2 lead; ZS-37-A-X592 adapter provided by 120VAC, powered by 24VDC
Detailed Specifications
| Product Category | Integrated, Remote, Monitor, and Manifold |
|---|---|
| Detection Principle | The PF3W series uses the Karman vortex principle; LFE uses Faraday electromagnetic induction; and PFUW is an external clamp-on pipe detection method. |
| Traffic range | PF3W7 series 0.5~250 L/min; PF3W7-U 10~250 L/min; PF3W7-X365 0.5~40 L/min; LFE 0.5~200 L/min (confirm by model) |
| Output Signal | 2 digital signals, or digital and analog (voltage/current); PF3W7-L supports IO-Link; 1.1 COM2 |
| Show | Dual-screen, three-color display: Main screen shows instantaneous flow; sub-screen displays temperature, setpoint, totalized value, or peak/bottom values. Rotates clockwise and counterclockwise. |
| Ingress Protection Rating | IP65 (PF3W7 Series, LFE); IP67 (PFUW) |
| Piping and Materials | Rc threaded pipe adapter (standard); PVC piping (-U); SUS316 compression fitting (-X365); C37 brass (LFE, -X8 optional 304 stainless steel) |
| Fluids | Water and Coolant; -U Series: Compatible with deionized water and liquid chemicals; -X365: Compatible with fluorinated liquids, subject to temperature and fluid restrictions; LFE: Compatible with water and non-corrosive conductive fluids. |
| Accessories | Manual flow control valve, temperature sensor, mounting bracket, M8 or M2 lead |
| manifold | Up to 10 channels; each channel can be configured with a remote or integrated display sensor, temperature sensor, flow control valve, and check valve. |
| Communication Data | IO-Link process data includes instantaneous flow rate, temperature, switch outputs, and diagnostic information, accessible via HMI for values and settings. |
| Power Accessories | ZS-37-A-X592 converts 120VAC to 4VDC output via M12 interface; power only, no input/output. |
| Verify | CE, RoHS; PF3W compliant with C-UL-US |
| Order Instructions | Confirm the model based on flow range, pipe material and fitting type, output method, presence of a regulating valve, and temperature sensor. |
Liquid Flow Sensor Model Comparison
| Model | Detection Principle | Traffic Range | Piping and Materials | Output and Display | Use Cases |
|---|---|---|---|---|---|
| PF3W7-Z | Kármán vortex street | 0.5~250 L/min | Threaded Tube Adapter, Z-Type Weight Reduction Adapter | Dual-screen tri-color display, switch or simulation, M8 cable | Universal Monitoring for Water and Coolant |
| PF3W7-L | Kármán vortex street | 0.5~250 L/min | Threaded Tube Adapter, Z-Type Weight Reduction Adapter | Dual-screen, three-color display; IO-Link 1.1 COM2 with switch output | Data acquisition and remote parameter configuration |
| PF3W7-U | Kármán vortex street | 10~250 L/min | PVC piping | Dual-screen, three-color display: switch or simulation | Deionized Water and Liquid Chemicals |
| PF3W7-X365 | Kármán vortex street | 0.5~40 L/min | SUS316 Compression Fitting with EPDM Seal | Dual-screen, three-color display with switch or analog simulation; no remote control | Circulation of Fluorinated Oils and Other Fluorinated Fluids |
| LFE | Faraday's Law of Electromagnetic Induction | 0.5~200 L/min | C37 Brass, -X8 is 304 Stainless Steel | Dual-screen, three-color display supporting 2 switch or switch plus analog channels. | Conductive fluid; circuit with low pressure drop requirement |
| Not a valid translation request. | Clamp-on External Inspection | Confirm by Pipeline and Model | Fixture installation: No liquid contact | Switch or Analog Output | Corrosive liquids and pipelines that are difficult to retrofit |
Application Areas
ConfirmSMC Liquid Flow Sensor Series PF3W/LFE/PFUWconfiguration?
Provide operating conditions, media type, and installation requirements—we'll help confirm the series, connections, and spare parts.